Cat. No. Range COD Prgm. ID CODL00 Low 0 – 150 mg/L 41 CODH00 Mid 0 – 1,500 mg/L 42 CODHP0 High 0 – 15,00 mg/L 43 2. Using the syringe provided, add 2.0 mL of sample to the COD vial for the low and mid range tests; add 0.2 mL of sample to the 3.
9mm thread caps, septums, 9mm 2ml HPlc screw vials are specifically designed for use with THERMO FISHER and other rotating or robotic arm samplers. 9mm2ml Hplc screw vials are manufactured in transparent glass, Type 1 Class A or Amber, Type 1 Class
The PrestoBlue® Cell Viability Reagent is the only live-cell viability reagent on the market able to provide robust data typically in as little as 10 minutes following reagent addition. All other resazurin-based cell viability reagents on the market require a one to four hour incubation with the reagent
Palintest™ COD Reagent Test Tubes. These COD reagent test tubes, with a range of 0 to 2000mg/L, are ideal for use in most laboratory and scientific environments where measuring COD. CHEMetrics™ COD Reagent Vials. Contain premeasured reagents for accurate, economical determination of COD.
Hach Company COD Digestion Vials, High Range Plus, 200 to 15,000 mg/L COD, pk/150 For determination of Chemical Oxygen Demand (COD) by the Reactor Digestion method. Hach Method 8000.
Low range vials. Contains everything needed (except distilled water) to perform 149 tests. Includes instruction book. Comes in cardboard box. 2-hour digestion time. Dichromate reactor digestion. A fresh reagent ampoule blank must be prepared for each series of tests; therefore the number of samples that can be tested with each kit will vary.
Use Thermo Scientific Orion AQUAfast Digestion Tubes, Reaction Tubes and Liquid Reagents with Orion AQUAfast colorimeters and Thermo Scientific Orion AquaMate Vis and UV-Vis spectrophotometers. Digestion and reaction tubes contain the precise amount of reagent, are made of special optical glass and fit the Orion™ AQUAfast COD165 thermoreactor.
Fix the adapter for 16 mm vials on the sample chamber . Switch the unit on using the [ON/OFF] key . The display shows the following: Lr (low range), Mr (medium range) or Hr (high range) Select the required test using the [MODE] key . Scroll Memory (SM)
Dispense the cell suspension into a multiwell culture plate or several small flasks. Add the antibiotic of choice to each well in a range of concentrations. For example, we suggest the following concentrations for Gibco Fungizone reagent: 0.25, 0.50, 1.0, 2.0, 4.0, and 8.0 µg/mL. 3.
11mm Snap Top Vial for THERMO FISHER. Aijiren’s Snap Vial is commonly used in HPLC analysis and is popular because of its convenient sealing. The glass of Aijiren snap vial is borosilicate hydrochloric acid glass that can hold samples and is not easy to change. The Cap of Snap Vial is Pe Cap, which is soft and easy to handle. Rated 4.7 /5
2ml snap top HPLC vial is made of Type 1 borosilicate glass. 2ml Snap hplc Vials mouth is wider opening. So 2ml snap top HPLC vial is easier to fill and provides a larger target area for the autosampler needle. That is to say, the 2ml snap top HPLC vial can
1. Pipette 5µL of each standard or unknown sample into the appropriate microplate wells (e.g., Thermo Scientific Pierce 96-Well Plates, Product No. 15041). 2. Add 250µL of the Coomassie Reagent to each well and mix with plate shaker for 30 seconds. 3.
COD Vials High Range 0-1500mg/L. WTW. Dichromate reactor digestion reagents for fast, easy, safe determination of low-, mid-, and high-range C.O.D. levels in wastewater. Premeasured reagent is packaged in flat-bottom ampules that are compatible with most spectrophotometers. Reagents have a two-year shelf life.