2947600: Buffer Solution Kit, Colour-coded, pH 4.01, pH 7.00 and pH 10.01, 500 mL. 400 - 25000 mg/L CaCO₃. AT1000 FOS/TAC Automatic Titrator Method. Contact Hach. 600 - 80000 mg/L CH₃COOH. AT1000 FOS/TAC Automatic Titrator Method.
Standard vials and Mercury Free. ChemLab Water COD vials for Chemical Oxygen Demand Analysis. Results displayed as O2 mg/l. Please note a reactor is required for sample digestion. The tube tests are in high-quality glass and the reagent tubes are shipped in special packaging to protect them during transport.
Methods for EPA Compliance Monitoring Hach TNTplus Vial Chemistries for COD (Hach Method 8000), Free and Total Chlorine (SM 4500-Cl G), Chromium VI (SM 3500-Cr B, D), Iron (Hach Method 8008), Ortho- (EPA 365.1) and Total Phosphate (EPA 365.1, 365.3), Ammonia (EPA 350.1), and Nitrite (EPA 353.2) are equivalent to the respective method referenced
Hach has more than 60 years of history dedicated to formulating and packaging high-quality reagents for water analysis. We understand your applications and formulate our reagents to ensure exceptional performance and deliver results you can trust, time after time. Our expertise extends beyond chemistry formulation to the complete reagent system.
COD Testing Advantages. COD is most suitable for rapid and frequent monitoring of treatment plant efficiency and water quality. This method is more accurate than BOD (with a 5-10% relative standard deviation) and it offers a relatively short analysis time (2-hour digestion time), compared to the 5-day BOD test.
Hach Australia Hach is dedicated to providing high-quality reagents for routine and challenging water analysis. ... Chemical Oxygen Demand (COD) TNTplus Vial Test ... See full list on au.hach.com
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk. No reagent blank necessary The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to
Chemistries, Reagents and Standards. Hach is dedicated to providing high-quality reagents for routine and challenging water analysis. Understanding our customer's applications has allowed us to formulate reagents that ensure exceptional performance and deliver trusted results. Hach chemistries are rigorously tested in combination with our
No Reagent Blank Necessary – The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money! Reduced errors – Automatic method detection with bar-coded vials.
DR3900 Laboratory Spectrophotometer for water analysis. With your daily routine of water analysis in mind the DR3900 spectrophotometer is optimised for safe processes and meaningful reports. Control-parameters like Ammonium, COD, Phosphate, Nitrogen and many others are easy to perform. The handling of tests and photometer is well designed to
Hach is dedicated to providing high-quality reagents for routine and challenging water analysis. Understanding our customers applications has allowed us to formulate reagents that ensure exceptional performance and deliver trusted results. See full list on hach.com
Jan 31, 2019 · The COD Digestion Vials, Low Range, pk/25 (Product # 2125825) as used in the standard COD method 8000, is specified to have a reagent blank absorbance that yields a result between 0 to 15 ppm COD versus a vial contained with only deionized water. In the method (Step 5) a second test vial is filled with deionized water and used as the reagent
Hach. For determination of Chemical Oxygen Demand (COD) by the Reactor Digestion Method, using TNTplus™ vials. Hach Method 8000. Range: 20-1500 mg/L COD. Reduce Errors with Bar-coded Vials No Reagent Blank Necessary Innovative Vial and Reagent Delivery Helpful package design CAUTION:.
Search results for 2125915 : COD Digestion Vials, High Range, pk/150