COD TNTplus Reagent Set, ULR, 1 to 60 mg/L COD 1-2 vials 25/pkg TNT820 Required apparatus Description Quantity/test Unit Item no. Blender, 2-speed , 120 VAC option 1 each 2616100 Blender, 2-speed, 240 VAC option 1 each 2616102
• Simultaneous digestion of up to 15 or 30 reagent vials (16 mm diameter) • Testing of COD in wastewater, sludge, rivers, lakes and streams • EPA approved for reporting purposes
COD Standard 394546 COD Standard (1000 ppm) 25 mL References: Standard Methods 5220, Chemical Oxygen Demand (COD). ASTM D1252, Chemical Oxygen Demand (Dichromate Oxygen Demand) of water. ISO 6060, Determination of the Chemical
COD kits CHEMetrics’ leakproof reagent vials contain premeasured solutions of sulfuric acids and potassium dichromate. To perform the COD determination, the analyst simply removes the Teflon® lined screw cap from the vial, adds sample to the vial, and replaces the cap. and replaces the cap.
Shop a large selection of COD Testing products and learn more about CHEMetrics COD Reagent Vials Cod Mercury Free Kit 25 tests/pk.; 0-150ppm, 10ppm MDL CHEMetrics COD Description No need to modify or recalibrate existing equipment or procedures
Cod found in: COD Digest Vial, Cod2 Lr, COD Digestion Vial, Cod2 Uhr, COD Tube Tests, Multi-Range COD Reagent Systems, AQUAfast COD Colorimeter, ECO 6.. The accu-TEST COD Reactor Block is an economical solution for digestion of chemical oxygen demand (COD) samples. samples.
Small reagent volumes used in Hach COD vials minimize the volume of spent silver, mercury and chromium waste. Customers in the contiguous 48 United States benefit from the availability of the ezCOD waste recycling program, which provides comprehensive transportation and disposal of COD vials.
Items to collect Description Quantity Manganese III COD Reagent Vials, 20–1000 mg/L COD 1–2 Blender, 2-speed 1 DRB200 reactor 1 Pipet, TenSette ®, 0.1–1.0 mL 1 Pipet tips, for TenSette ® Pipet, 0.1–1.0 mL 2 Test tube rack 1 Water, deionized 0.5 mL Refer
2020/9/2 · The measurement may be inaccurate and a hot reagent vial could damage the digital instrument. Hach Method 8000 for COD in wastewater is approved by the United States Environmental Protection Agency (USEPA) in 40 CFR 136.3, and it also obeys the operating principles of Standard Methods for the Examination of Water and Wastewater (Standard Methods) 5220 D (COD via Closed
Shop a large selection of COD Testing products and learn more about CHEMetrics COD Reagent Vials:Testing and Filtration:Water Testing and Environmental Cod Test Kit 25 tests/pk.; Description No need to modify or recalibrate existing equipment or procedures
Reagecon worlds largest producer of Physical & Chemical Standards, supplier of Laboratory Equipment Consumables and Chemicals Subscribe to receive exclusive offers and the
COD Analysis package Orlab offers economical COD Analysis package. The package consist of COD Reactor, Pre-programed Colorimeter and pk/25 COD Reagent vials with a stand to hold the vials. Photometer pre-programmed for COD of all ranges (LR, HR and
Include the reagent packs of 25, instructions, and accessories. Simply determine which parameter(s) you're interested in and order. Reagents require a thermoreactor.
Simultaneous digestion of up to 15 or 30 reagent vials (16 mm diameter) Testing of COD in wastewater, sludge, rivers, lakes and streams EPA accepted for reporting purposes COD can be determined in as little as 15 minutes Features Fully automatic 110V