Hach 2125915 COD Digest Vial, High Range, 20-1500mg/L (Pack of 150) Visit the Hach Company Store. Price: $247.00 ($16.47 / 10 Items) Enhance your purchase. This fits your . Make sure this fits by entering your model number. Manufactured by Hach.
Low-range COD reagent vials 0 to 150 mg/L (ppm) 10 Yes Yes 21258-15/25 B1010 100 0 to 150 mg/L (ppm) 10 No No 25650-15/25 B0010 100 Standard-range COD reagent vials 0 to 1500 mg/L (ppm) 30 Yes Yes 21259-15/25 B1015 100 0 to 1500 mg/L (ppm) 30
Product #: 2415951. GBP Price: Contact Us. Cuvette test (Ø 16 mm) completely equipped with all reagents, optimised for reliable measuring results and easy handling. TNT = Test 'N Tube. 16 mm TNT products can be evaluated on DR900 only.
These COD vials are premixed and ready to use. There are several types of reagents available commercially: EPA-compliant reagents: These vials comply with EPA method 410.4 and Standard Methods 5220D. These reagents use the formulation for this method
Description. 13mm barcoded COD vials for Chemical Oxygen Demand Analysis. With auto test recognition (in compatible systems) there is no simpler way to analyse COD. LCI400 and LCI500 meet ISO 15705:2003-01. Results displayed as O 2 mg/l. Please note a
For determination of high range Chemical Oxygen Demand (COD) by the Reactor Digestion method. US EPA approved for wastewater analysis using Hach Method 8000. Range: 20 -1500 mg/L COD. Pack of 25 vials. EPA Approved
Chemical oxygen demand (COD) is the amount of dissolved oxygen that must be present in water to oxidize chemical organic materials, like petroleum. COD is used to gauge the short-term impact wastewater effluents will have on the oxygen levels of receiving waters.
116 mg/L COD2 – 30 = 86 mg/L COD In summary, you can measure COD with Hach’s COD2 Reagent. However, you must compensate for chloride and ammonia interferences in this method. After accounting for these interferences, you obtain a result
2017/5/27 · Hach Associate Login I am a Hach Associate and would like to login. Login Contact Us Have Sales Contact Me Request to be contacted by a sales person. Need Support? Reach out to our support team Or please select your country or region Europe Österreich
COD Vials Kit. Catalog No.: K-7365*. Range: 0-1500 ppm (HR) USEPA-accepted. Method: Dichromate Reactor Digestion. Kit comes in a cardboard box and contains everything needed to perform up to 149 tests (except distilled water): 150 vials and instruction book.
2016/4/6 · The most common test method involves using COD vials – sample is pipetted into the vial where it mixes with the reagents already present in the vial. This is then reacted at high temperatures, producing a colour change. This colour change is analysed in a colorimeter, which reads out the result of
2019/10/9 · It is rugged and has a large, clear screen, with easy to use navigation, making it great for use in the field. The DR1900 portable spectrophotometer. The DR1900 will accept the following vial/cell sizes: Most 13mm LCK/COD vials (not all LCK vials are suitable for use in DR1900).
16mm Camlab Water COD vials for Chemical Oxygen Demand Analysis. Results displayed as O2 mg/l. Please note a reactor is required for sample digestion. The tube tests are in high-quality glass and the reagent tubes are shipped in special packaging to protect them during transport. All COD tests are available with a set of 25 tubes.
Small reagent volumes used in Hach COD vials minimize the volume of spent silver, mercury and chromium waste. Customers in the contiguous 48 United States benefit from the availability of the ezCOD waste recycling program, which provides comprehensive