methods for COD vial digestion. The accu-TEST COD Reactor Block maintains temperature to within 2 oC of 150 C for consistent results with an operational temperature range of Amb. +5 oC to 155 C. A safety shield is available
CW/24.20.721 for medium range CW/24.20.722 for high range Please note: As of April 2021, the packaging of the tubes has changed and they now feature a round bottom.
Dichromate - The dichromate method is adapted from the standard EPA and ISO methods for determination of COD, which are approved to measure COD concentrations ranging up to 1500 mg/L O 2. For samples with expected concentrations in the high range of 0 to 15000 mg/L O 2 , the dichromate reagents can be used for accurate COD determination.
COD2 Digestion Vials, Mercury-Free Formulation. Range: 20-1500 mg/L COD. Pack of Cod Tube at Thomas Scientific Cod Tube found in: COD Tube Tests, Digestion Reagent Tubes for COD, ECO 6 Thermoreactors for COD
methods for COD vial digestion. The accu-TEST COD Reactor Block maintains temperature to The accu-TEST COD Reactor Block maintains temperature to within 2 o C of 150 o C for consistent results with a temperature range of 100 o C to 155 o C.
2021/05/23 · Dichromate - The dichromate method is adapted from the standard EPA and ISO methods for determination of COD, which are approved to measure COD concentrations ranging up to 1500 mg/L O 2. For samples with expected concentrations in the high range of 0 to 15000 mg/L O 2 , the dichromate reagents can be used for accurate COD determination.
2019/05/21 · Only the Low Range COD Digestion vials (Range of 3-150 mg/L COD) and High Range COD vials (Range of 20-1500 mg/L COD) are USEPA approved for wastewater analyses, utilizing Oxygen Demand, Chemical-Reactor Digestion COD Method 8000 ULR, LR, HR, HR plus+.
Three measurement ranges to satisfy each need: Low range (LR): 0 to 150 mg/L O2. Medium range (MR): 0 to 1500 mg/L or 0 to 1000 mg/L O2. High range (HR):
HI93754G-25 COD Medium Range Reagent Vials, ISO Method (25 tests) The HI93754G-25 are reagent vials that follow the ISO approved method for the medium range determination of chemical oxygen demand (COD) using a compatible benchtop photometer.
Details of Chemical Oxygen Demand Test: 2mL of a water or watse water sample are added to a 16mm glass culture tube containing the digestion reagent and a catalyst. The tube is capped with a polypropylene, PTFE lined cap and heated in a block digester at 150C for 2 hours. The orange Hexavalent chromium is reduced to a greenish trivalent chromium.
Pricing and Availability. Chemical Oxygen Demand Standard, 300 ppm COD, Ricca Chemical. Potassium Acid Phthalate in Water.For Chemical Oxygen Demand in Water. (Non-Regulated) Pricing and Availability. COD Standard, 300ppm (1mL = 0.3mg COD) (Potassium Acid Phthalate in Water), Certified, 0.300mg/mL ±0.003, LabChem™.
For determination of high range Chemical Oxygen Demand (COD) by the Reactor Digestion method. US EPA approved for wastewater analysis using Hach Method 8000. Range: 20 -1500 mg/L COD. Pack of 150 vials.
COD Digestion Vials, High Range Plus, 200 to 15,000 mg/L COD, pk/25 Product #: 2415925 USD Price: $44.65 Add to Cart
COD2 Digestion Vials Method: Reactor Digestion Range: 0-150 mg/L COD Pack of 25 vials