4 Oxygen Demand, Chemical, Dichromate Method (multi-range: 40.0, 150, 1500, 15,000 mg/L) Table 2 Chloride concentration limits in the sample (continued) Vial range Column 1 (maximum mg/L
2019/09/18 · The samples then cool and the samples are tested using a spectrophotometer. The chemical oxygen demand value will be read in mg/L for both total COD (tCOD) and soluble COD (sCOD). For samples with a concentration of 0 to 150 mg/L, use the low range COD vials. For higher concentrations the high range COD vials (0-1500 mg/L) should be used.
In Stock - Ships within 1 week. Contains mercury. Dispose of according to local, state and federal regulations. For determination of high range Chemical Oxygen Demand (COD) by the Reactor Digestion method. US EPA approved for wastewater analysis using Hach Method 8000. Range: 20 -1500 mg/L COD. Pack of 25 vials.
Economical 180units waster water quality test ready to use reagents high range chemical oxygen demand with 25 vials US $78.00 / Box 1 Box (Min. Order) CN Zhejiang Ditexi Technology Co., Ltd. 2 YRS 50.0% Contact Supplier
In addition, we offer a COD digestor and photometers for low-range (0-150 ppm) and high-range (0
For determination of high range Chemical Oxygen Demand (COD) by the Reactor Digestion method. US EPA approved for wastewater analysis using Hach Method 8000. Range: 20 -1500 mg/L COD. Pack of 150 US EPA approved for wastewater analysis using Hach Method 8000.
2018/10/10 · Chemical Oxygen Demand 1. Oxygen Demand, Chemical DOC316.53.01099 USEPA1 Reactor Digestion Method2 Method 8000 0.7 to 40.03 mg/L COD (ULR); 3 to 150 mg/L COD (LR); 20 to 1500 mg/L COD (HR); 200 to 15,000 mg/L COD (HR Plus)
2021/03/09 · Discover this high-range chemical oxygen demand (COD) photometer available from CHEMetrics. COD is used to measure contamination levels in wastewater. A-7325 is CHEMetrics Single Analyte Meter (SAM) for high
high-range vials increased with increased digestion time. However, the additional 2-hour digestion still allowed only a small fraction of ammonia to be oxidized in the high range vials. Therefore, the oxidation of ammonia in the
Consult HACH LANGE's entire The Science of Chemical Oxygen Demand catalogue on DirectIndustry. Page: 1/24will require 40 mg mercuric sulfate to effect-ively mask the chloride interference. In some instances, mercuric sulfate
Chemical Oxygen Demand (COD Vials) LR COD: 0 - 150 mg/L HR COD: 0 - 1500 mg/L HR+ COD: 0 - 15,000 mg/L SAFETY INFORMATION COD reagent vials contain sulfuric acid,
The HI94754C-25 are barcode reagent vials that follow the dichromate method for the high range determination of chemical oxygen demand (COD) using a compatible benchtop photometer. These high quality reagents are manufactured in our state-of-the-art facility and are clearly marked with the lot number and expiration date on each box for traceability. Pre-dosed reagents for ease of use Barcoded
Find COD (Chemical Oxygen Demand) Reagent, Reagent Sets, Standards Hach is dedicated to providing high-quality reagents for routine and challenging water analysis. Understanding our customers applications has allowed us to
Chemical Oxygen Demand. Chemical Oxygen Demand (COD) is a measure of the biologically available and inert organic matter that is susceptible to oxidation by a strong oxidizing agent. The Hanna COD method is based on the well-established closed dichromate-reflux colorimetric method. The colorimetric measurement of COD is faster and easier to